Methods of M-Series MetaData Array Access |
Methods of M-Series MD Array Access:
Get SanTricity from CSWEB
https://qsweb.quantum.com/wiki/tiki-index.php?page=Q-Series+Disks
[root@M330_01nh ~]# vncpasswd
Password: <set_pw>
Verify: <set_pw>
/etc/init.d/vncserver start
The LSI CLI used in the majority of cases is located on the MDC at /opt/SMgr/client/SMcli
[root@M330_01nh ~]# SMcli -A
Starting auto discovery.
......
Auto discovery operation successful.
[root@M330_01nh ~]# SMcli -d -v
Qarray1 Qarray1a Qarray1b Optimal
QD6000 Qarray1a Qarray1b Needs Attention
Note: The SMagent which is usually started on a M-Series Appliance by default, needs to be running.
[root@M330_01nh ~]# SMagent status
SMagent (pid 1601) is running...
https://qwikipedia.brainkeeper.net//index.php?action=workspace.page&ZDPOFMWE=0ZRrk9OS