How to Check the Status of a Storage Node Power Supply using the CLI


Overview

This topic describes how to check the status of a power supply unit (PSU) in the different Lattus Storage Nodes models.

 


S10 Storage Node

  1. Enter the following command via the CLI:

# ipmitool sdr type "Power Supply"

 

Output displays similar to the following example:

 

PSU1 AC Lost     | 94h | ok  |  0.0 | Power Supply AC lost
PSU1 PWR Detect  | 97h | ok  |  0.0 | Presence detected
PSU2 AC Lost     | 9Ch | ok  |  0.0 | Presence detected
PSU2 PWR Detect  | 9Fh | ok  |  0.0 | Presence detected

 


S20 Storage Node

  1. Enter the following command via the CLI:

# ipmitool sdr type "Power Supply"

 

 

Output displays similar to the following example:

 

PSU1 AC Lost     | 94h | ok  |  0.0 | Power Supply AC lost
PSU1 PWR Detect  | 97h | ok  |  0.0 | Presence detected
PSU2 AC Lost     | 9Ch | ok  |  0.0 | Presence detected
PSU2 PWR Detect  | 9Fh | ok  |  0.0 | Presence detected

 


S20 Model 2 Storage Node

  1. Enter the following command via the CLI:

# ipmitool raw 0x6 0x52 0x7 0x5a 0x1 0x92

 

Depending on the PSU status, one of the following displays:

 


S30 Storage Node

  1. Enter the following command via the CLI:

# ipmitool raw 0x6 0x52 0x7 0x5a 0x1 0x92

 

Depending on the PSU status, one of the following displays:

 

 

 


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



This page was generated by the BrainKeeper Enterprise Wiki, © 2018