iSCSI Bridge
WebGUI
-
Launch a supported web browser.
-
Enter the IP address of the iSCSI bridge in the browser.
-
The login screen appears.
-
On the login screen, enter the same credentials used for an SSH connection
-
Select the Login button.
After successful login, you will be directed to the ‘System’ page, where general information about the 8100T will be displayed. On here, you can continuously monitor the operational status of the bridge to ensure it is functioning properly. Key real-time system details relating to firmware version, uptime, hardware status, and network ports is readily available on the dashboard.
Select the ‘Management’ tab for permissions. You may change the default password here. Save the configuration and diagnostics information in file format by selecting the corresponding button(s) as shown in the screenshot below.
Note: Please reference these files when contacting support for additional assistance. Once generated, they will be automatically saved to your Downloads folder.
-
Under the Management tab, an option to update firmware is also provided. To download the latest firmware version, visit www.atto.com (or) contact ATTO Technical Support.
-
Click on Update Firmware and point to the location of the firmware (.zbd file).
-
Once the firmware update is complete, click on Reboot to enable the new firmware.
Note: This feature requires firmware version 2.06 or later. Please update your device to the latest firmware to enable support for this feature.
The iSCSI bridge includes support for e-mail notifications to help administrators stay informed of critical system events and status changes. This feature allows the bridge to automatically send alert messages (or) notifications to designated e-mail addresses depending on the severity of the event occurred – allowing IT teams to improve overall system reliability and significantly reduce downtime.
-
Under the Management tab, click Configure to enable E-mail notifications for your bridge.
-
To enable E-mail notifications, slide the toggle to green. Please also toggle Server TLS to green.
Note: Server TLS must be enabled to verify the origin of traffic.
Enter your SMTP server and server’s port in the SMTP Server Address and Server Port fields.
-
Enter a from address in the Sender Address field.
-
Enter the username and password associated with the SMTP server.
Note: If unsure of your SMTP configuration, consult your SMTP server’s manager.
-
Configure up to five e-mail addresses to receive system alerts.
-
Based on the severity level of each event using the drop-down, you may also assign recipients to ensure that appropriate personnel are notified of warnings, errors, or critical failures.
-
Once configured, select Save to apply the configuration.
-
Test the configuration by selecting Send Test to send a test e-mail notification to all recipient address.
Note: To control the timing of e-mail alert notifications based on event severity, you may select a desired time delay between the receipt of alerts.
-
Select the Ethernet tab.
-
Review MP1 for management port 1, DP1 for Data Port 1, (or) DP2 for Data Port 2.
-
Change the IP address, subnet mask, and gateway of the management port or the data ports, accordingly.
-
You may change from static IP to DHCP, if desired. Ensure that you have access to the DHCP server in order to obtain the assigned address.
-
You can change the default MTU size of the Data Port(s) from 9000 to 1500, if needed.
Note: For optimal performance, MTU Size 9000 is recommended on the data ports.
-
Select Save Changes to automatically save your changes. No reboot is required.
Note: By default, all tape drives are mapped to all data ports. If custom mapping (or) ACL’s (Access Control Lists) is preferred, please refer to the Product Installation and Operations Manual for detailed information.
-
Select the iSCSI tab.
-
Displayed under this tab is a list of all the mapped iSCSI targets that you can login to from your operating system’s iSCSI initiator.
-
Currently logged in iSCSI initiators will be shown under Logins.
Note: This feature requires firmware version 2.06 or later.
The iSCSI bridge supports native tape hardware and media management capabilities allowing for simplified control of tape drives and media cartridges over the network. This makes it easier than ever to integrate tape into backup, archive, and compliance work flows reducing the need for physical touch points and streamlining operations.
-
To view connected tape devices (including media changer), click on the Storage tab.
Note: The
icon indicates that a tape cartridge is present in the tape drive. -
Click on the drop down icon
for access to log pages and tape commands. -
Select the appropriate command to execute a tape operation.
-
Load: load a tape cartridge
-
Eject: eject a tape cartridge
-
Rewind: move the tape to the beginning
-
Quick Erase: rewind and perform a quick erase
-
Long Erase: rewind and perform a long erase
-
Command Line Interface (CLI)
The command line interface (CLI) provides access, configuration, and monitoring for iSCSI bridge services through a set of ASCII commands. CLI commands are entered through the SSH session.
CLI commands are context sensitive and generally follow a standard format:
[Get|Set] Command [Parameter1|Parameter2] followed by the return or enter key
Additional Information
-
CLI commands are case insensitive: you may type all upper or all lower case or a mixture. Upper and lower case in this manual and the help screen are for clarification only.
-
Commands generally have three types of operation: get, set and immediate.
-
The get form returns the value of a parameter or setting and is an informational command.
-
Responses to get commands are followed by Ready.
-
The set form is an action that changes the value of a parameter or configuration setting. It may require a restart of the system before it is implemented. The restart can be accomplished by using a separate FirmwareRestart command if not prompted to reboot. A number of set commands may be issued before restart command.
-
Immediate commands are set commands which are executed right away and do not require a Save Configuration command.
-
Responses to Immediate commands are either an error message or data results followed by Ready.
Table 1: Command Conventions
| Symbol | Indicates |
|---|---|
| [ ] | Required entry |
| <> | Optional entry |
| | | Pick one of |
| … | Ellipses, repetition of preceding item |
| \n | End of line |
| - | A range (6 – 9 = 6, 7, 8, 9) |
| el | Ethernet LUN (0 <= el <= 1024) |
| dp | Ethernet Data port number (1 <= dp <= 2) |
| sasConn | SAS connector name (A) |
| mp | Ethernet Management port number (mp1) |
The following error messages may be returned by the Command line Interface
ERROR. Invalid Command. Type 'Help' for command list. ERROR. Wrong/Missing Parameters
Usage: <usage string>
ERROR. Command Not Processed
A summary of the Command Line Interface commands and their defaults is given below. Only those commands which have a "set" component that can be stored in non-volatile memory have a default listed. Commands which have no default values associated with them have a blank entry in that column of the table. Commands which are not present in the specified unit list "N/A" in that column.
| Command | Default Value |
|---|---|
| AccessControl | disabled |
| AccessEntry | |
| CertGen | |
| CertInfo | |
| ClearCliLog | |
| ClearEventLog | |
| ControllerName | |
| CoreDumpInfo | |
| Date | |
| DNSDomain | |
| DNSNameServer | |
| DumpCliLog | |
| DumpConfiguration | |
| DumpEventLog | |
| EmailDelay | |
| EmailFromAddress | |
| EmailNotify | |
| EmailNotifyAddress | |
| EmailPassword | |
| EmailServerAddress | |
| EmailServerPort | |
| EmailServerStartTls | |
| EmailServerTls | |
| EmailTest | |
| EmailUsername | |
| EncryptionKey | Unique keys |
| EthCongestionAlgorithm | cubic |
| EthFlowControl |
DP1 enabled DP2 enabled MP1 auto |
| EthMTU |
DP1 9000 DP2 9000 MP1 1500 |
| EthPort |
DP1 - - DP2 - - MP1 - - |
| EthSack | enabled |
| EthStats | |
| Exit | |
| FirmwareRestart | |
| FlashStatus | |
| Help | |
| Info | |
| IPAddress |
DP1 10.0.0.1 DP2 172.16.0.1 MP1 192.168.0.1 |
| IPGateway | |
| IPSubnetMask |
DP1 255.0.0.0 DP2 255.240.0.0 MP1 255.255.0.0 |
| IPV6Address |
DP1 fd00:: 2 DP2 fd00::3 MP1 fd00::1 |
| IPV6DHCP |
DP1 disabled DP2 disabled MP1 disabled |
| IPV6Gateway |
|
| IPV6Prefix |
DP1 64 DP2 64 MP1 64 |
| iSCSIChangeTargetSuffix | |
| iSCSICHAP | |
| iSCSICHAPMode | disabled |
| iSCSILatency | |
| iSCSILogins | |
| iSCSIMap | |
| iSCSIMappingMode | automatic |
| iSCSISetPorts | |
| iSCSIShowMaps | |
| iSCSITargetCreate | |
| iSCSITargetDelete | |
| iSCSIUnMap | |
| Licenses | |
| Password | Unique. See the bottom of the unit for default password |
| Ping | |
| RestoreConfiguration | |
| SASConnectorStats | |
| SASPortList | |
| SendEOMDeferredError | disabled |
| SFPInfo | |
| ShowCartridge | |
| ShowConnections | |
| ShowDevices | |
| TapeCommand | |
| TapeLogPage | |
| Temperature | |
| Timesync | enabled |
| TimesyncServer | |
| TimeZone | Time zone: America/New_York |
| TimeZoneList | |
| Uptime |
AccessControl enables (or) disables access control on a target node. Access to the target node is keyed to the iSCSI qualified name of whitelisted initiators in the target's access control list.
Commands
set AccessControl [Target Name | target ID] [enabled | disabled]
get AccessControl [Target Name | target ID | all]
AccessEntry allows the addition (or) deletion of an initiator entry from the access control list of a target node. The initiator name is converted to lower case and must be between 16 and 223 characters.
Note: For set AccessEntry, delete is optional when specifying an initiator name, but is required if specifying 'all'.
Commands
set AccessEntry [Target name | target ID] [initiator name<delete> | all [delete]]
get AccessEntry [Target name | target ID | all]
Deletes existing self-signed HTTPS certificates and generates new self-signed HTTPS certificates. This operation could take several minutes to complete.
Command
CertGen
Displays information about the current HTTPS certificates.
Command
CertInfo
Clears the contents of the CLI command log.
Command
ClearCliLog
Clears the contents of the event log.
Command
ClearEventLog
ControllerName provides a descriptive ASCII name assigned to the unit. This field is used by applications to identify individual units. The specified name can be up to a maximum of 32 characters. If the name contains spaces, it must be enclosed in quotation marks.
Commands
set ControllerName [name]
get ControllerName
Displays information concerning all core dumps stored by a prior fault.
Command
CoreDumpInfo
Sets/displays the current date and time, in the format of YYYY-MM-DD HH:MM:SS.
Note: When using this command to configure the date, Timesync must already be disabled.
Commands
set Date [YYYY-MM-DD] [HH:MM:SS]
get Date
Configures the global value for the DNS domain.
Up to 6 domains can be specified, each seperated by a space. The list can be cleared by calling set with Clear as the value.
Commands
set DNSDomain [domain url] x 6 | Clear]
get DNSDomain
Configures the global value for the DNS name server. Up to 3 IPv4 or IPv6 name servers can be specified, each seperated by a space. The list can be cleared by calling set with 'Clear' as the value.
Commands
set DNSNameServer [[IPv4 Address | IPv6 Address] x 3 | Clear]
get DNSNameServer
Dumps the contents of the CLI command log to the current CLI session.
Command
DumpCliLog
Dumps the configuration of the unit.
Command
DumpConfiguration
Dumps the contents of the event log to the current CLI session. With no parameters, the last 2048 entries are displayed. The optional parameter all specifies all entries will be displayed. An optional numeric parameter specifies the maximum number of newest entries to display.
Command
DumpEventLog <NumEntries | all>
Configure a delay between email notifications for the specified level. During the delay time notifications (if any) are accumulated and sent following the expiration of the delay. Configurable levels include informative and warning. The delay is specified in hours and must be 0, 1, 2, 4, 8, 24, or 168.
Commands
set EmailDelay [level | all] [delay]
get EmailDelay [level | all]
EmailFromAddress configures the email address that this system will use to talk to the email server. Full email address is a fully qualified Internet email address, not more than 50 characters long. Specify delete to remove the address.
Commands
set EmailFromAddress [full email address | delete]
get EmailFromAddress
EmailNotify turns on and off email notification.
Commands
set EmailNotify [enabled | disabled]
get EmailNotify
EmailNotifyAddress configures notification addresses. Index is a number between 1 and 5, inclusive. Full email address is a fully qualified Internet email address, not more than 50 characters long. The level must be all, warning, critical or none. This is the minimum level of severity in order for the event to trigger an email notification. Specify delete to remove the address.
Commands
set EmailNotifyAddress [index] [[[full email address] [level]] | delete]
get EmailNotifyAddress <index | All>
EmailPassword sets the password used to authenticate the login to the SMTP email server. The password must not be more than 50 characters. A password is not required if the email server does not require authentication.
Command
set EmailPassword
EmailServerAddress configures the address of the server that should be contacted in order to send out emails. Either an IP address or a fully qualified domain (e.g. mail.myserver.com) may be specified. Specify delete to remove the server.
Commands
set EmailServerAddress [[IP address | name] | delete]
get EmailServerAddress
EmailServerPort configures the port number then should be used when sending emails via the email server. Specify delete to remove the server port.
Commands
set EmailServerPort [port (1 - 65535) | delete]
get EmailServerPort
EmailServerStartTls, when enabled, is used to prompt an email server that the client wishes to upgrade the connection from an insecure connection to a secure one. STARTTLS upgrades an insecure connection to a secure connection via TLS protocol.
Commands
set EmailServerStartTls [enabled | disabled]
get EmailServerStartTls
EmailServerTls when enabled uses the Transport Layer Security (TLS) protocol to encrypt email communication sent via the Simple Mail Transfer Protocol (SMTP).
Commands
set EmailServerTls [enabled | disabled]
get EmailServerTls
Send a test email notification to all configured recipients.
Command
EmailTest
EmailUsername sets the username used to authenticate the login to the SMTP email server. The username must not be more than 50 characters. A username is not required if the email server does not require authentication. Specify delete to remove the username.
Commands
set EmailUsername [username | delete]
get EmailUsername
Allows the SSH/SFTP server-side encryption keys to be generated (or) displayed. Displaying the encryption keys will cause all available server-side public keys to be displayed, as well as the signatures of the server-side private keys.
Revoking existing keys can be performed with the Generate option.
Command
EncryptionKey [Generate | Display]
Configures the congestion algorithm for Ethernet traffic on the unit's data ports.
Commands
set EthCongestionAlgorithm [cubic | reno]
get EthCongestionAlgorithm
Sets the PAUSE frame behavior for the given data port(s). The enabled and disabled settings affect both rx and tx.
Commands
set EthFlowControl [DP[n] | all] [enabled | disabled]
get EthFlowControl [DP[n] | all]
Configures the MTU, (or) maximum transmission unit (Frame Size), used by the specified ethernet port. Standard equates to 1500 and jumbo 9000.
Commands
set EthMTU [DP[n]] [296 - 9024 | standard | jumbo]
get EthMTU [DP[n] | MP[n] | all]
Lists the available Ethernet ports, current status (Up/Down), and link speed. Specifying a port name followed by enabled (or) disabled configures the port to be persistently enabled (or) disabled, respectively.
Commands
set EthPort [DP[n] | MP[n] | all] [enabled | disabled]
get EthPort
Configures the SACK (Selective Acknowledgements) networking parameter. SACK is a refinement of TCP's traditional cumulative acknowledgements.
Commands
set EthSack [enabled | disabled]
get EthSack
Displays port statistics for the selected Ethernet port.
Command
get EthStats [DP[n] | MP[n] | all]
Terminates the current CLI session over SSH. This command relaunches the CLI interface if used during a serial RS-232 session.
Command
Exit
Causes an immediate reboot of the unit.
Command
FirmwareRestart
Displays the status of a firmware update in progress, (or) the most recent firmware update if no update is in progress. By default, only fifteen lines of status are displayed. The argument verbose will result in up to two hundred lines of status being displayed, including the status of a root filesystem update in progress, (or) the most recent root filesystem update if no update is in progress.
Command
FlashStatus <verbose>
The Help command issued with no parameters displays a list of available CLI commands. When a CLI Command name is specified, a command usage string and command description is presented on the CLI.
Command
Help <command>
Displays version number and other system information for key components of the unit.
Command
Info
Configures the current IP address of any Ethernet port(s).
If IPDHCP is enabled, the get command reports the current IP address assigned by the network DHCP server, followed by the (DHCP) identifier.
Command
set IPAddress [DP[n] | MP[n]] [xxx.xxx.xxx.xxx]
get IPAddress [DP[n] | MP[n] | all]
Configures the current DHCP setting. DHCP allows acquisition of an IP address from a network DHCP server. When this option is disabled, the IP address used is specified by the IPAddress command.
Commands
set IPDHCP [DP[n] | MP[n] | all] [enabled | disabled]
get IPDHCP [DP[n] | MP[n] | all]
Enable (or) disable an iperf3 server to aid network configuration and troubleshooting.
Commands
set Iperf3Server [enabled | disabled]
get Iperf3Server
Configures the current default gateway used by the specified Ethernet port.
Commands
set IPGateway [DP[n] | MP[n] | all] [IP Address]
get IPGateway [DP[n] | MP[n] | all]
Configures the current subnet masks used by the specified Ethernet port.
Commands
set IPSubnetMask [DP[n] | MP[n] | all] [xxx.xxx.xxx.xxx]
get IPSubnetMask [DP[n] | MP[n] | all]
Configures the current IPv6 address of any Ethernet port(s).
If IPV6DHCP is enabled, the get command reports the current IP address assigned by the network DHCP server, followed by the (DHCP) identifier.
Commands
set IPV6Address [DP[n] | MP[n]] [IPv6 Address] | [IPv6 Address/Prefix]
get IPV6Address [DP[n] | MP[n] | all]
Configures the current DHCPv6 setting. DHCP allows acquisition of an IP address from a network DHCP server. When this option is disabled, the IP address used is specified by the IPV6Address command.
Commands
set IPV6DHCP [DP[n] | MP[n] | all] [enabled | disabled]
get IPV6DHCP [DP[n] | MP[n] | all]
Configures the current default gateway used by the specified Ethernet port.
Commands
set IPV6Gateway [DP[n] | MP[n] | all] [IP Address]
get IPV6Gateway [DP[n] | MP[n] | all]
IPV6Prefix controls the current IPv6 prefix of any Ethernet port(s).
Commands
set IPV6Prefix [DP[n] | MP[n]] [Prefix length]
get IPV6Prefix [DP[n] | MP[n] | all]
Automatic mapping mode only. Change the default iSCSI qualified name (IQN) suffix.
The changeable suffix begins following the serial number in the IQN formatted as follows:
iqn.yyyy-mm.<naming authority>:<unit serial number>.<changeable suffix>
The changeable suffix must be 1-32 characters in length. Executing the command without providing an argument reverts the changeable suffix to the default.
Command
iSCSIChangeTargetSuffix [Target ID | name] <new changable suffix>
Specifies the incoming and outgoing usernames/passwords for iSCSI CHAP sessions.
Passwords are case sensitive, 12 to 16 characters, and cannot contain spaces, tabs, (or) the following characters: ( ) . ; ' " `
Usernames are case sensitive, 4 to 223 characters, and cannot contain the following characters: ~ ! @ # $ ^ & ( ) + [ ] { } * ; : ' " . , % | < > ? / \ = `
The in password is for authentication of the initiator by the target. It is used for both one-way and two-way authentication. There is only one out username/password pair per target.
If discovery is specified, the setting will apply to CHAP during discovery sessions.
Note: Access Control must be enabled and iSCSICHAPMode set to one-way (or) two-way for the CHAP password to apply.
EXAMPLES:
-
Display CHAP credentials for discovery and for all targets.
get iSCSICHAP all
-
Display CHAP credentials for target ID 0's access entry
iqn.initiator.00get iSCSICHAP 0 iqn.initiator.00
-
Display CHAP credentials for target name
iqn.target.1with an access entry ofiqn.initiator.01get iSCSICHAP iqn.target.1 iqn.initiator.01
-
Set the in CHAP credentials for target ID 2's access entry
iqn.initiator.0A, with usernameuser1and passwordpa$$worD35410set iSCSICHAP 2 in iqn.initiator.0A user1 pa$$worD35410
-
Set the out CHAP credentials for the target name
iqn.target.3, with usernameuser2and passwordP@ssW0Rd!8833set iSCSICHAP iqn.target.3 out user2 P@ssW0Rd!8833
-
Set the in CHAP credentials for discovery, with username
user_discoveryand passwordp@$$wOrDdiscoverset iSCSICHAP discovery in user_discovery p@$$wOrDdiscover
Command
set iSCSICHAP [[Target name | target ID] [in [Access entry] | out] | [discovery] [in | out]] [username] [password]
get iSCSICHAP all | discovery | [[Target name | target ID] <Access entry>]
iSCSICHAP specifies the type of CHAP to be used for initiator logins.
In One-way authentication, the target authenticates the initiator using the in CHAP password, but the initiator does not authenticate the target.
In Two-way authentication, an additional level of security enables the initiator to authenticate the target using the out CHAP password.
Disabled means no authentication will be enforced and any initiator will have access to the target.
If discovery is specified, the selected CHAP authentication will apply to discovery sessions.
Commands
set iSCSICHAPMode [Target Name | target ID | discovery] [disabled | one-way | two-way]
get iSCSICHAPMode [Target Name | target ID | discovery | all]
Captures and reports iSCSI read and write latency on a per- target basis. All times are in microseconds and are an average of multiple commands sampled during a short period when this CLI command is executed. Reads (or) writes must be occurring when executing this command.
Length represents the command length in bytes seen during the sampling period.
Response time is the time from receipt of an iSCSI command until a response and possibly data has been transmitted back to the initiator.
Queue time is how long a command that's ready has waited before being submitted to the device. Applies to writes only.
Device time represents how long the SAS device took to complete a command.
Response to Command time is the time between transmitting a response for one command and beginning iSCSI processing of the next. Includes host delay.
R2Ts are the number of Ready to Transfer messages that were needed to fetch all data for a write command. Applies to writes only.
Command
iSCSILatency
Displays details of the initiators currently logged in (active), and optionally of initiators previously logged in as well (inactive). Displays active logins by default and both active and inactive if the all argument is specified.
Command
iSCSILogins <all>
Manual mapping mode only. Map a device to an iSCSI target. Use CLI commands iSCSIShowMaps and ShowDevices to see the target and device IDs.
Command
iSCSIMap [Target ID | name] [Device ID] [LUN]
Changes the iSCSI mapping mode. In automatic mode devices are assigned to predefined iSCSI targets based on SAS topology. iSCSI targets are only accessible when devices are attached. Manual mode allows user creation and deletion of iSCSI targets and user mapping of devices to targets.
Changing the mapping mode may require a reboot before taking effect.
Commands
set iSCSIMappingMode [automatic | manual]
get iSCSIMappingMode
Configure the iSCSI target data port accessibility.
Command
iSCSISetPorts [Target ID | name] [DP1 | DP2 | all | none]
Display mapping details between iSCSI targets and devices.
Command
iSCSIShowMaps
Manual mapping mode only. Create an iSCSI target. The target name is formatted as follows:
iqn.yyyy-mm.<naming authority>:<unit serial number>.<IQN suffix>
The provided IQN suffix must be between 1-32 characters.
Command
iSCSITargetCreate [IQN suffix] [DP1 | DP2 | all | none]
Manual mapping mode only. Delete an iSCSI target.
Command
iSCSITargetDelete [Target ID | name]
Manual mapping mode only. Remove a mapping between device and iSCSI target. Use CLI commands iSCSIShowMaps (Immediate) and ShowDevices (Immediate) to see the target and device IDs.
Command
iSCSIUnMap [Device ID]
Displays the collection of relevant open source licenses used by the unit.
Command
Licenses
Specifies the password used for all interactive sessions that require a login. Password is case sensitive, 8 to 32 characters, must contain at least one numeric character {0-9} and cannot contain the following special characters: {space, tab, ", ', \, ;}.
Command
set Password
Ping will send an ICMP echo request to the specified host via the specified network interface.
Command
Ping [DP[n] | MP[n]] [IP Address] <count <size>>
Restores the configuration back to defaults. Use the default option to revert the SSH/SFTP admin password back to the original password. All Ethernet configuration settings and iSCSI maps are also reset to defaults. The default
option is equivalent to pressing and holding the reset button for 5 seconds to restore settings. The unit will reboot as part of the process.
Command
RestoreConfiguration <default>
Displays SAS PHY error statistics. The argument verbose will print out the legend for the header values.
Command
SASConnectorStats <verbose>
Displays SAS PHY link information.
Command
SASPortList
End Of Medium (EOM) deferred error configuration controls early warning deferred errors generated by SpeedWrite.
Enable this setting if there are issues with end of tape handling.
Commands
set SendEOMDeferredError [enabled | disabled]
get SendEOMDeferredError
SFPInfo displays information about the specified SFP(s).
Command
get SFPInfo [DP1 | DP2 | all]
Display tape cartridge details.
Command
ShowCartridge [Device ID]
Displays active network connections and their type.
Command
ShowConnections
Display SAS device details.
Command
ShowDevices
Execute a tape drive command. Supported commands are: load: load a tape cartridge
-
eject: eject a tape cartridge
-
rewind: move the tape to the beginning
-
quickerase: rewind and perform a quick erase
-
longerase: rewind and perform a long erase
-
retension: rewind, then wind to the end of the reel, then rewind again
Operations may take several seconds to several hours to complete. Use ShowDevices (Immediate) to see the status of ongoing commands.
Command
set TapeCommand [Device ID] [command]
Retrieve portions of a log page. Supported pages are:
-
WRErrors: Read and Write errors. Portions of log pages 0x02 and 0x03.
-
TapeAlert: TapeAlert. Portions of log page 0x2E. DevStats: Device Statistics. Portions of log page 0x14.
-
DataCompression: Data Compression. Portions of log page 0x1B.
Command
TapeLogPage [Device ID] [selection]
Displays the current operating temperatures of the various temperature sensors in degrees Celsius.
Command
get Temperature
Configures the timesync service. Timesync automatically adjusts the system date and time based on well-known time servers.
Command
set Timesync [enabled | disabled] get Timesync
Assign up to three timesync servers separated by spaces or use delete to remove all.
Commands
set TimesyncServer [List of up to 3 timesync servers | delete]
get TimesyncServer
Timezone sets/displays the time zone.
Commands
set TimeZone [[EST | CST | MST | PST] | [Index from TimeZoneList command]]
get TimeZone
Displays available time zones for setting the timezone.
Command
TimeZoneList
Returns the time [days hrs:min:sec] since the last reboot.
Command
Uptime