Storage Traps
The following table lists Storage trap details.
RAS Ticket Help
The Online_Help_Filename column lists the service (RAS) ticket help file associated with the SNMP trap. If you are logged into the DXi remote management console, you can access the RAS ticket help file by doing one of the following:
- Enter the following path in a web browser:<dxi-hostname or IP-address>/online_help/<online_help_filename>.
- Click the View Recommended Actions link on the Ticket Details page.
Keep in mind that traps issued without a FRU do not have RAS ticket help files associated with them, including all Information traps and certain Error traps.
FRU_ID |
Event_ID |
Trap_Level |
Trap_Details |
Online_Help_Filename |
---|---|---|---|---|
0301 | 7 | Error | storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Hardware fault | 0301-TP003.htm |
0301 | 25 | Error | storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Communication failure | 0301-TP005.htm |
0301 | 114 | Error | storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : RPA Parity error | RaidCtrl.htm |
0301 | 120 | Error | storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Component is failed | RaidCtrl.htm |
0301 | 124 | Error | storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Needs attention | RaidCtrl.htm |
0301 | 126 | Error | storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Component is removed | RaidCtrl.htm |
0301 | 127 | Error | storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Component in service mode | RaidCtrl.htm |
0301 | 128 | Error | storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Component is suspended | RaidCtrl.htm |
0302 | 22 | Error | storage subsystem chassis <ParFRU_Inst> drive <FRU_Inst> : Drive failure | 0302-TP001.htm |
0302 | 23 | Error | storage subsystem chassis <ParFRU_Inst> drive <FRU_Inst> : Drive removed | 0302-TP001.htm |
0302 | 117 | Warning | storage subsystem chassis <ParFRU_Inst> drive <FRU_Inst> : Drive is bypassed | RaidDrv.htm |
0302 | 118 | Warning | storage subsystem chassis <ParFRU_Inst> drive <FRU_Inst> : Drive is replaced | RaidDrv.htm |
0302 | 119 | Error | storage subsystem chassis <ParFRU_Inst> drive <FRU_Inst> : Drive is unresponsive | RaidDrv.htm |
Error | storage subsystem chassis <ParFRU_Inst> drive <FRU_Inst> : Component is failed | |||
0303 | 7 | Error | storage subsystem chassis <FRU_Inst> : Hardware fault | 0303-TP001.htm |
0304 | 9 | Error | storage subsystem chassis <ParFRU_Inst> power supply <FRU_Inst> : Not present | 0304-TP001.htm |
0304 | 17 | Error | storage subsystem chassis <ParFRU_Inst> power supply <FRU_Inst> : Power supply failure | 0304-TP001.htm |
Error | storage subsystem chassis <ParFRU_Inst> power supply <FRU_Inst> : Component is failed | |||
0305 | 9 | Error | storage subsystem chassis <ParFRU_Inst> fan <FRU_Inst> : Not present | 0305-TP001.htm |
0305 | 19 | Error | storage subsystem chassis <ParFRU_Inst> fan <FRU_Inst> : Fan failure | 0305-TP001.htm |
Error | storage subsystem chassis <ParFRU_Inst> fan <FRU_Inst> : Component is failed | |||
030B | 115 | Error | storage subsystem chassis <ParFRU_Inst> storage subsystem volume <FRU_Inst> : Component is degraded | RaidVol.htm |
030B | 120 | Error | storage subsystem chassis <ParFRU_Inst> storage subsystem volume <FRU_Inst> : Component is failed | RaidVol.htm |
030C | 34 | Error | storage subsystem chassis <ParFRU_Inst> storage subsystem temperature sensor <FRU_Inst> : High temperature | 0301-TP002.htm |
030C | 36 | Information | storage subsystem chassis <ParFRU_Inst> storage subsystem temperature sensor <FRU_Inst> : Over temperature | 0301-TP002.htm |
030C | 126 | Error | storage subsystem chassis <ParFRU_Inst> storage subsystem temperature sensor <FRU_Inst> : Component is removed | RaidSensor.htm |
030E | 126 | Error | storage subsystem chassis <ParFRU_Inst> storage subsystem SFP <FRU_Inst> : Component is removed | RaidSfp.htm |
Error | storage subsystem chassis <ParFRU_Inst> storage subsystem battery <FRU_Inst> : Component is degraded | |||
030F | 120 | Error | storage subsystem chassis <ParFRU_Inst> storage subsystem battery <FRU_Inst> : Component is failed | RaidBattery.htm |
030F | 123 | Error | storage subsystem chassis <ParFRU_Inst> storage subsystem battery <FRU_Inst> : Component is near expiration | RaidBattery.htm |
030F | 126 | Error | storage subsystem chassis <ParFRU_Inst> storage subsystem battery <FRU_Inst> : Component is removed | RaidBattery.htm |
0312 | 116 | Information | storage subsystem chassis <ParFRU_Inst> storage subsystem alarm <FRU_Inst> : Component is disabled | RaidAlarm.htm |
0312 |
124 |
Error |
storage subsystem chassis <ParFRU_Inst> storage subsystem alarm <FRU_Inst> : Needs attention |
RaidAlarm.htm |
0312 |
126 |
Error |
storage subsystem chassis <ParFRU_Inst> storage subsystem alarm <FRU_Inst> : Component is removed |
RaidAlarm.htm |
0313 |
125 |
Error |
storage subsystem chassis <ParFRU_Inst> storage subsystem support CRU <FRU_Inst> : Component is receiving no input |
RaidCru.htm |
0313 |
126 |
Error |
storage subsystem chassis <ParFRU_Inst> storage subsystem support CRU <FRU_Inst> : Component is removed |
RaidCru.htm |
0314 |
7 |
Error |
storage subsystem chassis <ParFRU_Inst> storage subsystem tray <FRU_Inst> : Hardware fault |
RaidTray.htm |
|
|
Information |
"Alarm <AlarmId>: encl=<xx> |
slot=<xx>" |
|
|
Information |
Alarm <AlarmId>: unit=<xx> |
|
|
|
Information |
Alarm <AlarmId>: vport=<xx> |
|
|
|
Information |
Storsave mode setup |
|
|
|
Information |
RAID Unit <(DXi6xxx) RaidVolume> Storsave Policy = performance . Setting to balance. |
|
|
|
Information |
RAID Unit<(DXi6xxx) RaidVolume> Storsave Policy = protection . Setting to balance. |
|
|
|
Information |
RAID Unit <(DXi6xxx) RaidVolume> Storsave Policy = unknown . Setting to balance. |
|