Storage Traps

The following table lists Storage trap details.

RAS Ticket Help

The Online_Help_Filename column lists the service (RAS) ticket help file associated with the SNMP trap. If you are logged into the DXi remote management console, you can access the RAS ticket help file by doing one of the following:

  • Enter the following path in a web browser:<dxi-hostname or IP-address>/online_help/<online_help_filename>.
  • Click the View Recommended Actions link on the Ticket Details page.

Keep in mind that traps issued without a FRU do not have RAS ticket help files associated with them, including all Information traps and certain Error traps.

FRU_ID

Event_ID

Trap_Level

Trap_Details

Online_Help_Filename

0301 7 Error storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Hardware fault 0301-TP003.htm
0301 25 Error storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Communication failure 0301-TP005.htm
0301 114 Error storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : RPA Parity error RaidCtrl.htm
0301 120 Error storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Component is failed RaidCtrl.htm
0301 124 Error storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Needs attention RaidCtrl.htm
0301 126 Error storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Component is removed RaidCtrl.htm
0301 127 Error storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Component in service mode RaidCtrl.htm
0301 128 Error storage subsystem chassis <ParFRU_Inst> controller <FRU_Inst> : Component is suspended RaidCtrl.htm
0302 22 Error storage subsystem chassis <ParFRU_Inst> drive <FRU_Inst> : Drive failure 0302-TP001.htm
0302 23 Error storage subsystem chassis <ParFRU_Inst> drive <FRU_Inst> : Drive removed 0302-TP001.htm
0302 117 Warning storage subsystem chassis <ParFRU_Inst> drive <FRU_Inst> : Drive is bypassed RaidDrv.htm
0302 118 Warning storage subsystem chassis <ParFRU_Inst> drive <FRU_Inst> : Drive is replaced RaidDrv.htm
0302 119 Error storage subsystem chassis <ParFRU_Inst> drive <FRU_Inst> : Drive is unresponsive RaidDrv.htm
    Error storage subsystem chassis <ParFRU_Inst> drive <FRU_Inst> : Component is failed  
0303 7 Error storage subsystem chassis <FRU_Inst> : Hardware fault 0303-TP001.htm
0304 9 Error storage subsystem chassis <ParFRU_Inst> power supply <FRU_Inst> : Not present 0304-TP001.htm
0304 17 Error storage subsystem chassis <ParFRU_Inst> power supply <FRU_Inst> : Power supply failure 0304-TP001.htm
    Error storage subsystem chassis <ParFRU_Inst> power supply <FRU_Inst> : Component is failed  
0305 9 Error storage subsystem chassis <ParFRU_Inst> fan <FRU_Inst> : Not present 0305-TP001.htm
0305 19 Error storage subsystem chassis <ParFRU_Inst> fan <FRU_Inst> : Fan failure 0305-TP001.htm
    Error storage subsystem chassis <ParFRU_Inst> fan <FRU_Inst> : Component is failed  
030B 115 Error storage subsystem chassis <ParFRU_Inst> storage subsystem volume <FRU_Inst> : Component is degraded RaidVol.htm
030B 120 Error storage subsystem chassis <ParFRU_Inst> storage subsystem volume <FRU_Inst> : Component is failed RaidVol.htm
030C 34 Error storage subsystem chassis <ParFRU_Inst> storage subsystem temperature sensor <FRU_Inst> : High temperature 0301-TP002.htm
030C 36 Information storage subsystem chassis <ParFRU_Inst> storage subsystem temperature sensor <FRU_Inst> : Over temperature 0301-TP002.htm
030C 126 Error storage subsystem chassis <ParFRU_Inst> storage subsystem temperature sensor <FRU_Inst> : Component is removed RaidSensor.htm
030E 126 Error storage subsystem chassis <ParFRU_Inst> storage subsystem SFP <FRU_Inst> : Component is removed RaidSfp.htm
    Error storage subsystem chassis <ParFRU_Inst> storage subsystem battery <FRU_Inst> : Component is degraded  
030F 120 Error storage subsystem chassis <ParFRU_Inst> storage subsystem battery <FRU_Inst> : Component is failed RaidBattery.htm
030F 123 Error storage subsystem chassis <ParFRU_Inst> storage subsystem battery <FRU_Inst> : Component is near expiration RaidBattery.htm
030F 126 Error storage subsystem chassis <ParFRU_Inst> storage subsystem battery <FRU_Inst> : Component is removed RaidBattery.htm
0312 116 Information storage subsystem chassis <ParFRU_Inst> storage subsystem alarm <FRU_Inst> : Component is disabled RaidAlarm.htm

0312

124

Error

storage subsystem chassis <ParFRU_Inst> storage subsystem alarm <FRU_Inst> : Needs attention

RaidAlarm.htm

0312

126

Error

storage subsystem chassis <ParFRU_Inst> storage subsystem alarm <FRU_Inst> : Component is removed

RaidAlarm.htm

0313

125

Error

storage subsystem chassis <ParFRU_Inst> storage subsystem support CRU <FRU_Inst> : Component is receiving no input

RaidCru.htm

0313

126

Error

storage subsystem chassis <ParFRU_Inst> storage subsystem support CRU <FRU_Inst> : Component is removed

RaidCru.htm

0314

7

Error

storage subsystem chassis <ParFRU_Inst> storage subsystem tray <FRU_Inst> : Hardware fault

RaidTray.htm

 

 

Information

"Alarm <AlarmId>: encl=<xx>

slot=<xx>"

 

 

Information

Alarm <AlarmId>: unit=<xx>

 

 

 

Information

Alarm <AlarmId>: vport=<xx>

 

 

 

Information

Storsave mode setup

 

 

 

Information

RAID Unit <(DXi6xxx) RaidVolume> Storsave Policy = performance . Setting to balance.

 

 

 

Information

RAID Unit<(DXi6xxx) RaidVolume> Storsave Policy = protection . Setting to balance.

 

 

 

Information

RAID Unit <(DXi6xxx) RaidVolume> Storsave Policy = unknown . Setting to balance.

 

See Also IconSee Also