I/O Server Traps

The following table lists I/O Server trap details.

RAS Ticket Help

The Online_Help_Filename column lists the service (RAS) ticket help file associated with the SNMP trap. If you are logged into the DXi remote management console, you can access the RAS ticket help file by doing one of the following:

  • Enter the following path in a web browser:<dxi-hostname or IP-address>/online_help/<online_help_filename>.
  • Click the View Recommended Actions link on the Ticket Details page.

Keep in mind that traps issued without a FRU do not have RAS ticket help files associated with them, including all Information traps and certain Error traps.

FRU_ID

Event_ID

Trap_Level

Trap_Details

Online_Help_Filename

0101

7

Error

I/O Server <FRU_Inst> : Hardware fault

0101-TP003.htm

0101

8

Error

I/O Server <FRU_Inst> : Software fault

0101-TP003.htm

0101

10

Warning

I/O Server <FRU_Inst> : Over voltage

0101-TP001.htm

0101

11

Warning

I/O Server <FRU_Inst> : Under voltage

0101-TP001.htm

0101

31

Error

I/O Server <FRU_Inst> : Low voltage

0101-TP001.htm

0101

33

Warning

I/O Server <FRU_Inst> : Low temperature

0101-TP002.htm

0101

34

Error

I/O Server <FRU_Inst> : High temperature

0101-TP002.htm

0101

35

Information

I/O Server <FRU_Inst> : Under temperature

0101-TP002.htm

0101

36

Warning

I/O Server <FRU_Inst> : Over temperature

0101-TP002.htm

0101

52

Error

I/O Server <FRU_Inst> : Not responding

0101-TP003.htm

0101

77

Error

I/O Server <FRU_Inst> : Configuration mismatch

IOS_ConfigMismatch.htm

0101

95

Error

I/O Server <FRU_Inst> : Nonrecoverable temperature

0101-TP002.htm

0101

96

Error

I/O Server <FRU_Inst> : Nonrecoverable voltage

0101-TP001.htm

0101

115

Error

I/O Server <FRU_Inst> : Component is degraded

0101-TP003.htm

0102

9

Error

I/O Server I/O Server drive <FRU_Inst> : Not present

0102-TP001.htm

0102

22

Error

I/O Server I/O Server drive <FRU_Inst> : Drive failure

IosDrvBoot.htm

0102

24

Error

I/O Server I/O Server drive <FRU_Inst> : IO Error

0102-TP001.htm

0103

9

Error

I/O Server I/O Server FC HBA <FRU_Inst> : Not present

0103-TP001.htm

0103

14

Error

I/O Server I/O Server FC HBA <FRU_Inst> : Link failure

0103-TP001.htm

0103

28

Error

I/O Server I/O Server FC HBA <FRU_Inst> : FC communication failure

0103-TP001.htm

0104

14

Error

I/O Server Ethernet port <FRU_Inst> : Link failure

IOS_EtherFail.htm

0104

29

Error

I/O Server Ethernet port <FRU_Inst> : Communication failure (internal bus)

IOS_EtherFail.htm

0106

9

Error

I/O Server power supply <FRU_Inst> : Not present

IOS_PowerSupplyNotPresent.htm

0106

17

Error

I/O Server power supply <FRU_Inst> : Power supply failure

IOS_PowerSupplyFail.htm

0107

9

Error

I/O Server fan <FRU_Inst> : Not present

0107-TP002.htm

0107

18

Error

I/O Server fan <FRU_Inst> : Low speed (tach counts)

IOS_FanFail.htm

0107

97

Warning

I/O Server fan <FRU_Inst> : High speed (tach counts)

IOS_FanFail.htm

0107

98

Error

I/O Server fan <FRU_Inst> : Critical speed

IOS_FanFail.htm

0107

99

Error

I/O Server fan <FRU_Inst> : Nonrecoverable speed

IOS_FanFail.htm

011A

146

Error

I/O Server Server memory <FRU_Inst> : Imminent hardware failure expected

ImminentHWFail.htm

011A

147

Error

I/O Server Server memory <FRU_Inst> : Memory misconfiguration detected

DIMMisconfig.htm

0806

7

Error

IPMI Controller <FRU_Inst> : Hardware fault

IPMI.htm