I/O Server Traps
The following table lists I/O Server trap details.
RAS Ticket Help
The Online_Help_Filename column lists the service (RAS) ticket help file associated with the SNMP trap. If you are logged into the DXi remote management console, you can access the RAS ticket help file by doing one of the following:
- Enter the following path in a web browser:<dxi-hostname or IP-address>/online_help/<online_help_filename>.
- Click the View Recommended Actions link on the Ticket Details page.
Keep in mind that traps issued without a FRU do not have RAS ticket help files associated with them, including all Information traps and certain Error traps.
FRU_ID |
Event_ID |
Trap_Level |
Trap_Details |
Online_Help_Filename |
---|---|---|---|---|
0101 |
7 |
Error |
I/O Server <FRU_Inst> : Hardware fault |
0101-TP003.htm |
0101 |
8 |
Error |
I/O Server <FRU_Inst> : Software fault |
0101-TP003.htm |
0101 |
10 |
Warning |
I/O Server <FRU_Inst> : Over voltage |
0101-TP001.htm |
0101 |
11 |
Warning |
I/O Server <FRU_Inst> : Under voltage |
0101-TP001.htm |
0101 |
31 |
Error |
I/O Server <FRU_Inst> : Low voltage |
0101-TP001.htm |
0101 |
33 |
Warning |
I/O Server <FRU_Inst> : Low temperature |
0101-TP002.htm |
0101 |
34 |
Error |
I/O Server <FRU_Inst> : High temperature |
0101-TP002.htm |
0101 |
35 |
Information |
I/O Server <FRU_Inst> : Under temperature |
0101-TP002.htm |
0101 |
36 |
Warning |
I/O Server <FRU_Inst> : Over temperature |
0101-TP002.htm |
0101 |
52 |
Error |
I/O Server <FRU_Inst> : Not responding |
0101-TP003.htm |
0101 |
77 |
Error |
I/O Server <FRU_Inst> : Configuration mismatch |
IOS_ConfigMismatch.htm |
0101 |
95 |
Error |
I/O Server <FRU_Inst> : Nonrecoverable temperature |
0101-TP002.htm |
0101 |
96 |
Error |
I/O Server <FRU_Inst> : Nonrecoverable voltage |
0101-TP001.htm |
0101 |
115 |
Error |
I/O Server <FRU_Inst> : Component is degraded |
0101-TP003.htm |
0102 |
9 |
Error |
I/O Server I/O Server drive <FRU_Inst> : Not present |
0102-TP001.htm |
0102 |
22 |
Error |
I/O Server I/O Server drive <FRU_Inst> : Drive failure |
IosDrvBoot.htm |
0102 |
24 |
Error |
I/O Server I/O Server drive <FRU_Inst> : IO Error |
0102-TP001.htm |
0103 |
9 |
Error |
I/O Server I/O Server FC HBA <FRU_Inst> : Not present |
0103-TP001.htm |
0103 |
14 |
Error |
I/O Server I/O Server FC HBA <FRU_Inst> : Link failure |
0103-TP001.htm |
0103 |
28 |
Error |
I/O Server I/O Server FC HBA <FRU_Inst> : FC communication failure |
0103-TP001.htm |
0104 |
14 |
Error |
I/O Server Ethernet port <FRU_Inst> : Link failure |
IOS_EtherFail.htm |
0104 |
29 |
Error |
I/O Server Ethernet port <FRU_Inst> : Communication failure (internal bus) |
IOS_EtherFail.htm |
0106 |
9 |
Error |
I/O Server power supply <FRU_Inst> : Not present |
IOS_PowerSupplyNotPresent.htm |
0106 |
17 |
Error |
I/O Server power supply <FRU_Inst> : Power supply failure |
IOS_PowerSupplyFail.htm |
0107 |
9 |
Error |
I/O Server fan <FRU_Inst> : Not present |
0107-TP002.htm |
0107 |
18 |
Error |
I/O Server fan <FRU_Inst> : Low speed (tach counts) |
IOS_FanFail.htm |
0107 |
97 |
Warning |
I/O Server fan <FRU_Inst> : High speed (tach counts) |
IOS_FanFail.htm |
0107 |
98 |
Error |
I/O Server fan <FRU_Inst> : Critical speed |
IOS_FanFail.htm |
0107 |
99 |
Error |
I/O Server fan <FRU_Inst> : Nonrecoverable speed |
IOS_FanFail.htm |
011A |
146 |
Error |
I/O Server Server memory <FRU_Inst> : Imminent hardware failure expected |
ImminentHWFail.htm |
011A |
147 |
Error |
I/O Server Server memory <FRU_Inst> : Memory misconfiguration detected |
DIMMisconfig.htm |
0806 |
7 |
Error |
IPMI Controller <FRU_Inst> : Hardware fault |
IPMI.htm |