DXi6900 Physical Characteristics

The following tables provide dimensions and other physical characteristics of the DXi6900 system components:

DXi6900 G1 Physical Characteristics

 

DXi6900 G1 Node

Array Module (RBOD)

Expansion Module (EBOD)

Height

2U, 3.4 inches (8.7 cm)

2U, 3.4 inches (8.7 cm)

2U, 3.4 inches (8.7 cm)

Width (side to side)

17.5 inches (44.4 cm)

17.8 inches (45.1 cm)

17.6 inches (44.6 cm)

Depth (front to back)

28.6 inches (72.6 cm)

21.8 inches (55.2 cm)

21.8 inches (60.2 cm)

Weight (stand alone)

53.0 pounds (24.0 kg)

59.0 pounds (26.8 kg)

57.0 pounds (25.9 kg)

Rack Space Required

2U

2U

2U

Air clearance

Open 4 in (10.2 cm) behind unit for proper air flow

DXi6900 G2 Physical Characteristics

 

DXi6900 G2 Node

Array Module (RBOD)

Expansion Module (JBOD)

Height

2U, 3.4 inches (8.7 cm)

2U, 3.4 inches (8.7 cm)

2U, 3.4 inches (8.7 cm)

Width (side to side)

17.5 inches (44.4 cm)

17.8 inches (45.1 cm)

17.6 inches (44.6 cm)

Depth (front to back)

28.6 Inches (72.6 cm)

21.8 inches (55.2 cm)

21.8 inches (60.2 cm)

Weight (stand alone)

49.4 pounds (22.4 kg)

59.0 pounds (26.8 kg) 57.0 pounds (25.9 kg)

Rack Space Required

2U

2U

2U

Air clearance

Open 4 in (10.2 cm) behind unit for proper air flow

DXi6900-S Physical Characteristics

 

DXi6900-S Node

Array Module (RBOD)

Expansion Module (JBOD)

Height

2U, 3.4 inches (8.7 cm)

2U, 3.4 inches (8.7 cm)

2U, 3.4 inches (8.7 cm)

Width (side to side)

17.5 inches (44.4 cm)

17.8 inches (45.1 cm)

17.6 inches (44.6 cm)

Depth (front to back)

28.6 inches (72.6 cm)

21.8 inches (55.2 cm)

21.8 inches (60.2 cm)

Weight (stand alone)

44.5 pounds (20.2 kg)

57 pounds (25.9 kg)

55 pounds (24.9 kg)

Rack Space Required

2U

2U

2U

Air clearance

Open 4 in (10.2 cm) behind unit for proper air flow

DXi6900 Storage Capacity

DXi6900 Storage Capacity

DXi6900 G1 / DXi6900 G2

Usable capacity

From 17 TB to 510 TB

Capacity increments

Each Array Module (RBOD) and Expansion Module (EBOD) provides 34 TB of usable capacity, licensable in 17 TB increments.
DXi6900-S

Usable capacity

From 34 TB to 544 TB

Capacity increments

Each Array Module (RBOD) and Expansion Module (EBOD) provides 68 TB of usable capacity, licensable in 34 TB increments.

DXi6900 Cable Drops

DXi6900 Cable Drops

Ethernet Cable Drops

DXi6900 G1 (3 x 1GbE ports and 2 x 10GbE ports) - 1 to 3 1GbE Ethernet connections and 1 to 2 10GbE Ethernet connections (optical or Twinax, see below) for NAS or OST connectivity, replication, and remote management.

DXi6900 G1 (7 x 1GbE ports and 2 x 10GbE ports) - 1 to 7 1GbE Ethernet connections and 1 to 2 10GbE Ethernet connections (optical or Twinax, see below) for NAS or OST connectivity, replication, and remote management.

DXi6900 G1 (3 x 1GbE ports and 4 x 10GbE ports) - 1 to 3 1GbE Ethernet connections and 1 to 4 10GbE Ethernet connections (optical or Twinax, see below) for NAS or OST connectivity, replication, and remote management.

DXi6900 G2 / DXi6900-S (3 x 1GbE ports) - 1 to 3 1GbE Ethernet connections for for NAS or OST connectivity, replication, and remote management.

DXi6900 G2 / DXi6900-S (6 x 10GbE ports) - 1 to 6 10GbE Ethernet connections (optical,Twinax, CAT6, see below) for NAS or OST connectivity, replication, and remote management.

Note: For Cisco 5000 Series Data Center Class switches, Quantum recommends using the approved 5 meter Twinax cable type that is shipped with the DXi6900 system. Otherwise, Quantum recommends using optical (SFP+) connectivity.

Note: The 10 GbE Copper (Twinax) cable options that Quantum provides do not support all switches. Please note the supported switches during the purchase-configuration process, and if the Twinax cables supplied by Quantum are not compatible with your switch, then you will need to provide your own compatible Twinax cables from your switch vendor. Be sure to have these available before the system installation takes place.

Ethernet Cables

10 GbE Optical Cable

(DXi6900 G1)

10 GbE Optical Cable

(DXi6900 G2 / DXi6900-S)

10 GbE Copper (Twinax) Cable

10 GBase-T CAT6 Cable

Fibre Channel Drops

1 to 6 Fibre Channel connections for path-to-tape/VTL data transfer.

Power Outlets

Node - 2 USA type 3-prong power outlets (Nema 5-15) or 2 C13 type 3‑prong power outlets (IEC320 C13).

Expansion Module (each) - 2 USA type 3-prong power outlets (Nema 5-15) or 2 C13 type 3‑prong power outlets (IEC320 C13). For additional information, see.

Virtual Device Limits and Hardware Interfaces

DXi6900 Virtual Device Limits and Hardware Interfaces

Interfaces

VTL backup target: 64 partitions maximum, 512 virtual tape drives (VTDs) maximum.

NAS backup target:128 shares maximum (NFS or CIFS)

OST backup target:100 storage servers maximum

Note: NFS version: NFSv3

Note: Samba version: 4.5.3

Hardware

DXi6900 G1

  • 3 ports 100/1000BASE-T Ethernet (RJ45 connector)
  • 2 ports 10GbE Ethernet (optical 10GBASE-SR via LC connector or Twinax copper 10GBASESFP+Cu via SFP+)
  • 6 ports 8 Gb Fibre Channel (LC connector)

Note: An optional network adapter may be added providing 4 additional 100/1000BASE-T Ethernet ports or 2 additional 10GbE Ethernet ports.

DXi6900 G2 / DXi6900-S

  • 3 ports 100/1000BASE-T Ethernet (RJ45 connector)
  • 1 to 6 ports 10GbE Ethernet (optical 10GBASE-SR via LC connector, Twinax copper 10GBASESFP+Cu via SFP+, or 10GBASE-T via CAT6A)
  • 1 to 6 ports 16 Gb Fibre Channel (LC connector)

DXi6900 G1 Power Requirements

DXi6900 G1 Power Requirements

Power Supplies and Cords

Node

Expansion Module (RBOD)

Two (2) hot-swappable redundant power supplies

Two (2) USA type 3-prong power cords with IEC320 C13 to Nema 5-15 connectors:

Two (2) C13 to C14 type 3-prong power cords with IEC320 C13 to IEC320 C14 connectors:

Voltage

Node

100–240 VAC

Expansion Module (RBOD)

100–240 VAC

Frequency

Node

50–60Hz

Array Module (RBOD)

50–60Hz

Expansion Module (EBOD)

50–60Hz

Maximum Operating

Node

586 Watts, 5.9A @100 VAC 2100 BTU/hr

586 Watts, 2.3A @240 VAC 2100 BTU/hr

Array Module (RBOD)

334 Watts, 3.3A @100 VAC 1140 BTU/hr 334 Watts, 1.4A @240 VAC 1140 BTU/hr

Expansion Module (EBOD)

228 Watts, 2.3A @100 VAC 780 BTU/hr

228 Watts, 1.0A @240 VAC 780 BTU/hr

Maximum Inrush

Maximum Configuration

81A @ 100 VAC 34A @ 240 VAC

DXi6900 G2 Power Requirements

DXi6900 G2 Power Requirements

Power Supplies and Cords

Node

Expansion Module (RBOD)

Two (2) hot-swappable redundant power supplies

Two (2) USA type 3-prong power cords with IEC320 C13 to Nema 5-15 connectors:

Two (2) C13 to C14 type 3-prong power cords with IEC320 C13 to IEC320 C14 connectors:

Voltage

Node

100–240 VAC

Expansion Module (RBOD)

100–240 VAC

Frequency

Node

50–60Hz

Array Module (RBOD)

50–60Hz

Expansion Module (EBOD)

50–60Hz

Maximum Operating

Node

613 Watts, 6.1A @100 VAC 2000 BTU/hr

613 Watts, 2.6A @240 VAC 2000 BTU/hr

Array Module (RBOD)

334 Watts, 3.3A @100 VAC 1140 BTU/hr

334 Watts, 1.4A @240 VAC 1140 BTU/hr

Expansion Module (EBOD)

228 Watts, 2.3A @100 VAC 780 BTU/hr

228 Watts, 1.0A @240 VAC 780 BTU/hr

Maximum Inrush

Maximum Configuration

95A @ 100 VAC 40A @ 240 VAC

Caution: To safeguard backups and to avoid potential data loss in the event of a power outage, Quantum recommends that you connect the DXi6900 to an uninterruptable power supply (UPS) with a minimum UPS capacity rating that meets the power requirements stated above.

DXi6900-S Power Requirements

DXi6900-S Power Requirements

Power Supplies and Cords

Node

Expansion Module (RBOD)

Two (2) hot-swappable redundant power supplies

Two (2) USA type 3-prong power cords with IEC320 C13 to Nema 5-15 connectors:

Two (2) C13 to C14 type 3-prong power cords with IEC320 C13 to IEC320 C14 connectors:

Voltage

Node

100–240 VAC

Expansion Module (RBOD)

100–240 VAC

Frequency

Node

50–60Hz

Array Module (RBOD)

50–60Hz

Expansion Module (EBOD)

50–60Hz

Maximum Operating

Node

468 Watts, 4.7A @100 VAC 1597 BTU/hr

468 Watts, 1.9A @240 VAC 1597 BTU/hr

Array Module (RBOD)

276 Watts, 2.8A @100 VAC 942 BTU/hr

276 Watts, 1.2A @240 VAC 942 BTU/hr

Expansion Module (EBOD)

168 Watts, 1.8A @100 VAC 573 BTU/hr

168 Watts, 0.8A @240 VAC 573 BTU/hr

Maximum Inrush

Maximum Configuration

59A @ 100 VAC 25A @ 240 VAC