DXi4700 Physical Characteristics
The following tables provide dimensions and other physical characteristics of the DXi4700 system components:
- DXi4700 G1 Physical Characteristics
- DXi4700 G2 Physical Characteristics
- DXi4700 Storage Capacity
- DXi4700 Cable Drops
- DXi4700 Interfaces
- DXi4700 G1 Power Requirements
- DXi4700 G2 Power Requirements
DXi4700 G1 Physical Characteristics
|
DXi4700 Node |
DXi4700 Expansion Module (JBOD) |
Height |
2U, 3.4 inches (8.7 cm) |
3.4 inches (8.7 cm) |
Width (side to side) |
17.5 inches (44.4 cm) |
17.6 inches (44.6 cm) |
Depth (front to back) |
28.6 Inches (72.6 cm) |
23.7 inches (60.2 cm) |
Weight (stand alone) |
61.0 pounds (27.7 kg) |
62.6 pounds (28.4 kg) |
Rack Space Required |
2U |
2U |
Air clearance |
Open 4 in (10.2 cm) behind unit for proper air flow |
DXi4700 G2 Physical Characteristics
|
DXi4700 Node |
DXi4700 Expansion Module (JBOD) |
Height |
2U, 3.4 inches (8.7 cm) |
3.4 inches (8.7 cm) |
Width (side to side) |
17.5 inches (44.4 cm) |
17.6 inches (44.6 cm) |
Depth (front to back) |
28.6 Inches (72.6 cm) |
23.7 inches (60.2 cm) |
Weight (stand alone) |
49.4 pounds (22.4 kg) |
59.2 pounds (26.8 kg) |
Rack Space Required |
2U |
2U |
Air clearance |
Open 4 in (10.2 cm) behind unit for proper air flow |
DXi4700 Cable Drops
DXi4700 Interfaces
DXi4700 Virtual Device Limits and Hardware Interfaces |
|
Interfaces |
VTL backup target (DXi4700 VTL and Multi-Protocol configurations only): 64 partitions maximum, 64 virtual tape drives (VTDs) maximum
NAS backup target (DXi4700 NAS and Multi-Protocol configurations only): 128 shares maximum (NFS or CIFS) OST backup target (DXi4700 NAS and Multi-Protocol configurations only): 100 storage servers maximum Note: NFS version: NFSv2 and NFSv3 Note: Samba version: 4.1.12 |
Hardware |
(Standard) 3 ports 100/1000BASE-T Ethernet: RJ45 connector (Optional) 2 ports 10 GbE Ethernet: Optical 10GBASE-SR via LC connector or Twinax copper 10GBASESFP+Cu via SFP+ (Optional) 2 ports 10 GBase-T CAT6 Ethernet: RJ45 connector (VTL and Multi-Protocol) 2-4 ports 8 Gb Fibre Channel: LC connector DXi4700 systems can contain either the optional 10 GbE Ethernet or 10 GBase-T CAT6 Ethernet hardware, but not both. |
DXi4700 G1 Power Requirements
DXi4700 Power Requirements |
||
Power Supplies and Cords |
Node Expansion Module (JBOD) |
Two (2) hot-swappable redundant power supplies |
Two (2) USA type 3-prong power cords with IEC320 C13 to Nema 5-15 connectors:
|
||
Two (2) C13 to C14 type 3-prong power cords with IEC320 C13 to IEC320 C14 connectors:
|
||
Voltage |
Node |
100–240 VAC |
Expansion Module (JBOD) |
100–240 VAC |
|
Frequency |
Node |
50–60Hz |
Expansion Module (JBOD) |
50–60Hz |
|
Inrush |
Node |
8.3A @ 100V 4.7A @ 240V |
Expansion Module (JBOD) |
16.1A @ 100V 4.7A @ 240V |
|
Maximum Operating |
Node |
4.4A @ 100V 1.8A @ 240V 440W 1501 BTU/Hr |
Expansion Module (JBOD) |
2.5A @ 100V 1.2A @ 240V 264W 901 BTU/Hr |
DXi4700 G2 Power Requirements
DXi4700 Power Requirements |
||
Power Supplies and Cords |
Node Expansion Module (JBOD) |
Two (2) hot-swappable redundant power supplies |
Two (2) USA type 3-prong power cords with IEC320 C13 to Nema 5-15 connectors:
|
||
Two (2) C13 to C14 type 3-prong power cords with IEC320 C13 to IEC320 C14 connectors:
|
||
Voltage |
Node |
100–240 VAC |
Expansion Module (JBOD) |
100–240 VAC |
|
Frequency |
Node |
50–60Hz |
Expansion Module (JBOD) |
50–60Hz |
|
Inrush |
Node |
6.4A @ 100V 4.1A @ 240V |
Expansion Module (JBOD) |
10.1A @ 100V 6.9A @ 240V |
|
Maximum Operating |
Node |
4.3A @ 100V 1.8A @ 240V 427W 1458 BTU/Hr |
Expansion Module (JBOD) |
2.5A @ 100V 1.1A @ 240V 244W 9831 BTU/Hr |
Caution: To safeguard backups in the event of a power outage, Quantum recommends that you connect the DXi4700 to a UPS (uninterruptable power supply).