DXi4700 Specifications
This section lists characteristics and specifications the DXi4700. These characteristics and specifications are categorized as follows:


|
DXi4700 G1 Node |
DXi4700 G1 Expansion Module (JBOD) |
Height |
2U, 3.4 inches (8.7 cm) |
3.4 inches (8.7 cm) |
Width (side to side) |
17.5 inches (44.4 cm) |
17.6 inches (44.6 cm) |
Depth (front to back) |
28.6 Inches (72.6 cm) |
23.7 inches (60.2 cm) |
Weight (stand alone) |
61.0 pounds (27.7 kg) |
62.6 pounds (28.4 kg) |
Rack Space Required |
2U |
2U |
Air clearance |
Open 4 in (10.2 cm) behind unit for proper air flow |
|
DXi4700 G2 Node |
DXi4700 G2 Expansion Module (JBOD) |
Height |
2U, 3.4 inches (8.7 cm) |
3.4 inches (8.7 cm) |
Width (side to side) |
17.5 inches (44.4 cm) |
17.6 inches (44.6 cm) |
Depth (front to back) |
28.6 Inches (72.6 cm) |
23.7 inches (60.2 cm) |
Weight (stand alone) |
49.4 pounds (22.4 kg) |
59.2 pounds (26.8 kg) |
Rack Space Required |
2U |
2U |
Air clearance |
Open 4 in (10.2 cm) behind unit for proper air flow |

DXi4700 Storage Capacity |
|
Usable capacity¹ |
From 5 TB to 135 TB |

DXi4700 Cable Drops |
||||||
Ethernet Cable Drops |
|
|||||
Ethernet Cables |
|
|||||
Fibre Channel Drops |
(DXi4700 VTL and Multi-Protocol configurations only) 1 to 2 Fibre Channel connections for data transfer. |
|||||
Power Outlets |
Node - 2 USA type 3-prong power outlets (Nema 5-15) or 2 C13 type 3-prong power outlets (IEC320 C13). Expansion Module (each) - 2 USA type 3-prong power outlets (Nema 5-15) or 2 C13 type 3-prong power outlets (IEC320 C13). . |

DXi4700 Virtual Device Limits and Hardware Interfaces |
|
Interfaces |
VTL backup target (DXi4700 VTL and Multi-Protocol configurations only): 64 partitions maximum, 64 virtual tape drives (VTDs) maximum (no more than 32 VTDs active at any one time) NAS backup target (DXi4700 NAS and Multi-Protocol configurations only): 128 shares maximum (NFS or CIFS) OST backup target (DXi4700 NAS and Multi-Protocol configurations only): 100 storage servers maximum Note: NFS version: NFSv3 Note: Samba version: 4.1.12 |
Hardware |
(Standard) 3 ports 100/1000BASE-T Ethernet: RJ45 connector (Optional) 2 ports 10 GbE Ethernet: Optical 10GBASE-SR via LC connector or Twinax copper 10GBASESFP+Cu via SFP+ (Optional) 2 ports 10 GBase-T CAT6 Ethernet: RJ45 connector (VTL and Multi-Protocol) 2-4 ports 8 Gb Fibre Channel: LC connector Note: DXi4700 systems can contain either the optional 10 GbE Ethernet or 10 GBase-T CAT6 Ethernet hardware, but not both. |

DXi4700 G1 Power Requirements |
||
Power Supplies and Cords |
Node Expansion Module (JBOD) |
Two (2) hot-swappable redundant power supplies |
Two (2) USA type 3-prong power cords with IEC320 C13 to Nema 5-15 connectors:
|
||
Two (2) C13 to C14 type 3-prong power cords with IEC320 C13 to IEC320 C14 connectors:
|
||
Voltage |
Node |
100–240 VAC |
Expansion Module (JBOD) |
100–240 VAC |
|
Frequency |
Node |
50–60Hz |
Expansion Module (EBOD) |
50–60Hz |
|
Maximum Operating |
Node |
4.4A @ 100V 1.8A @ 240V 440W 1501 BTU/Hr 혀¬ |
Expansion Module (JBOD) |
2.5A @ 100V 1.2A @ 240V 264W 901 BTU/Hr |
|
Inrush |
Node |
8.3A @ 100V 4.7A @ 240V |
Expansion Module (JBOD) |
16.1A @ 100V 6.8A @ 240V |
DXi4700 G2 Power Requirements |
||
Power Supplies and Cords |
Node Expansion Module (JBOD) |
Two (2) hot-swappable redundant power supplies |
Two (2) USA type 3-prong power cords with IEC320 C13 to Nema 5-15 connectors:
|
||
Two (2) C13 to C14 type 3-prong power cords with IEC320 C13 to IEC320 C14 connectors:
|
||
Voltage |
Node |
100–240 VAC |
Expansion Module (JBOD) |
100–240 VAC |
|
Frequency |
Node |
50–60Hz |
Expansion Module (EBOD) |
50–60Hz |
|
Maximum Operating |
Node |
4.3A @ 100V 1.8A @ 240V 427W 1458 BTU/Hr |
Expansion Module (JBOD) |
2.5A @ 100V 1.1A @ 240V 244W 832 BTU/Hr |
|
Inrush |
Node |
6.4A @ 100V 4.1A @ 240V |
Expansion Module (JBOD) |
10.1A @ 100V 6.9A @ 240V |
Caution: To safeguard backups in the event of a power outage, Quantum recommends that you connect the DXi4700 to a UPS (uninterruptable power supply). Two circuits should be used (one per power supply)
Caution: To safeguard backups and to avoid potential data loss in the event of a power outage, Quantum recommends that you connect the DXi4700 to an uninterruptable power supply (UPS) with a minimum UPS capacity rating that meets the power requirements stated above.

DXi6900 Climatic Environment | ||
Temperature |
Operating |
10° to 35°C (50° to 95°F) with a maximum temperature gradient of 10°C per hour Note: 35°C (95°F) is the maximum temperature for the DXi6900 at sea level. For every 1,000 feet (305 meters) of altitude, the maximum temperature is reduced by 0.9°C. |
Shipping and storage |
–20° to 60°C (4° to 140°F) with a maximum temperature gradient of 20°C per hour |
|
Relative humidity |
Operating |
20% to 80% (non-condensing) with a maximum humidity gradient of 10% per hour |
Shipping and storage |
5% to 95% (non-condensing) with a maximum humidity gradient of 10% per hour |
|
Altitude |
Operating |
–16m to 3048 m (–50 to 10,000 ft) |
Shipping and storage |
–16m to 10,600 m (–100 to 35,000 ft) |
|
DXi6900 Vibration and Shock |
||
Sine Vibration |
Operating |
Random 0.26 G’s, 5–350 Hz, Operational axis 10 minutes, psd: 0.0002 G2/Hz |
Non-operating |
Random 0.5 G’s, 5–350 Hz, Operational axis 10 minutes, psd: 0.0007 G2/Hz |
|
Shock Vibration |
Operating |
2 G’s for 11 ms, half-sine input, 3 shock pulses in both + and – directions operational axis |
Non-operating |
3.5 G’s for 11 ms, half-sine input, 3 shock pulses in both + and – directions operational axis |
|
DXi6900 Acoustic |
||
Acoustic output |
Operating |
Sound Pressure Level 72 dbA maximum at any operation position |
DXi6900 Agency Approvals |
||
EMC/Safety |
47 CFR part 15 Class A CNS 13438 Class A CISPR 22 Class A CISPR 24 Class A EN 55022 Class A EN 55024 EN 60590-1 EN 61000-3-2 EN 61000-3-3 IEC 60590-1 ICES-003 Class A VCCI V-3/2011-04 Class A (DXi6900 G1) VCCI V-3/2014-04 Class A (DXi6900 G2 / DXi6900-S) AS/NZS 3548 Class A KN22 Class A KN24 UL 60590-1 |
|
Immunity Tests
Standards: EN55024: 1998 +A1: 2001 +A2:2003 KN24 |
IEC 61000-4-2 (Ed. 2.0 2008-12) - Electrostatic Discharge (ESD) IEC 61000-4-3 (Ed. 3.1 2008-04) - Radiated RF Immunity IEC 61000-4-4 (Ed. 2.0 2004-07) - Electrical Fast Transient/Burst IEC 61000-4-5 (Ed. 2.0 2005-11) - Surge Immunity IEC 61000-4-6 (Ed. 2.2 2006-05) - Conducted RF Immunity IEC 61000-4-8 (Ed. 1.1 2001-03) - Magnetic Field IEC 61000-4-11 (Ed. 2.0 2004-03) - AC Dips and Interrupts |
Caution: The DXi4700 systems are designed to be installed in a rack enclosure. Ensure that the operating temperature inside the rack enclosure does not exceed the maximum rated ambient temperature. Do not restrict air flow to the DXi4700 components.