Pre-Installation Checklist

Prior to arriving on site to install an X200 system, use the following lap top set up and cables for communicating with the IPMI and data switches.

The Quantum VM installer consists of an OVA image which contains both the installation VM and the corresponding ActiveScale ISO.

Other requirements

The VM needs to be able to reach the different nodes which are being installed over the internal private VLANs of ActiveScale. This means that the network card in bridged mode needs to be connected to one of the switches of the ActiveScale systems and that that specific port on that switch needs to be in the same VLAN as the nodes which are being installed.

Power Requirements

Configuration Power Requirement
Twin Server with 90 drives 2400W each

Twin JBOD with 90 drives

1600W each

25/100GbE Data Switch

420W each

1GbE IPMI Switch

20W each

PDU Requirements

Planning ahead for power/ what we need to tell the customer